Possible Causes

Failed SmartDeviceBox, Firmware incompatibility, Poor contact in SmartDevice slot

How to Fix / Troubleshooting

Safety first: Disconnect power before inserting or removing SmartDevice modules.

Steps:

  • Remove SmartDevice module: Open the SmartDevice slot (usually on the top of the appliance) and carefully remove the module.
  • Inspect contacts: Check the module and slot contacts for dust or corrosion. Clean gently with a dry, lint-free cloth.
  • Reinsert and reset: Reinstall the module firmly, restore power, and follow Liebherr's pairing/reset instructions.

Remedy: If F17 persists, replace the SmartDevice module. If a new module does not resolve the error, the main control board's communication interface may be faulty.