E8
Logik High Temperature / Overload Protection Fault

Freezer displays E8 and may run continuously without reaching the set temperature; the compressor is hot to the touch.

Advertisements

Possible Causes

Blocked condenser coils, failed condenser fan (if fitted), poor ventilation around freezer, weak compressor or internal mechanical failure.

How to Fix / Troubleshooting

Safety first: Unplug the freezer before cleaning or working near the compressor and condenser. Allow hot components to cool.

  • Check ventilation: Ensure there is adequate clearance around the freezer (typically at least 5–10 cm at sides and rear). Do not push the unit tightly against the wall.
  • Clean condenser coils: Access the rear or bottom of the freezer and locate the condenser coils. Use a soft brush and vacuum to remove dust and lint. This is critical for Logik freezers with rear or bottom-mounted condensers.
  • Inspect condenser fan (if present): Some upright Logik freezers have a condenser fan near the compressor. Confirm it spins freely and runs when the compressor is on. Replace the condenser fan motor if seized or not running.
  • Check ambient temperature: Ensure the freezer is not installed in a very hot or unventilated room, which can trigger over-temperature faults.
  • Power reset: After cleaning and improving ventilation, unplug for 10 minutes, then reconnect. Monitor whether E8 clears and the temperature drops over several hours.

When to call a technician: If E8 persists despite good airflow and clean coils, the compressor may be weak or the sealed system may be compromised. These issues require professional diagnosis and repair.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Condenser Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.