E8
Teka Power Supply / Voltage Error Detection

Freezer shows E8 and may not maintain correct temperature; often related to power supply or voltage issues.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Low or unstable mains voltage, Internal PCB power supply failure, Loose mains connection at terminal block, Faulty line filter or surge suppressor

How to Fix / Troubleshooting

Safety: Unplug the freezer before inspecting electrical connections.

  • Check mains outlet: Test the wall socket with another appliance or a multimeter to ensure correct voltage and firm contact.
  • Inspect power cord: Look for cuts, kinks, or burn marks. Replace the cord if damaged.
  • Access terminal block: Remove the rear cover to inspect where the mains cable connects to the appliance. Tighten any loose screws and check for discoloration.
  • Inspect line filter / EMI module: If fitted, check for burnt smell or cracked casing. Replace if visibly damaged.
  • PCB power section: Examine the main PCB for burnt components in the power supply area (near where mains enters). If damaged, replace the PCB.
  • Use a voltage stabilizer if supply is unstable: In areas with frequent brownouts, a stabilizer can prevent recurring E8 errors.

Test: Restore power and monitor if E8 reappears. If it does despite stable mains, the PCB likely needs replacement.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control Board (Power Supply Section)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements