13
American Standard Ignition Lockout – Repeated Flame Failure

Error code 13: Furnace locks out after several failed ignition attempts, requiring a power reset.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Contaminated flame sensor, intermittent gas valve coil, loose burner ground, improper combustion air supply to the American Standard furnace.

How to Fix / Troubleshooting

Safety: Turn off power and gas before cleaning or tightening components.

Error 13 is a hard lockout after multiple failed ignition cycles.

  • Reset lockout:
    • Turn off power for at least 30 seconds, then restore.
  • Clean the flame sensor and check the ground:
    • Follow the same cleaning steps as for other flame sensor faults.
    • Tighten ground screws on the burner rack and control board.
  • Check combustion air:
    • For sealed combustion models, inspect the intake PVC for blockages.
    • Ensure the furnace room has adequate ventilation if using indoor air.
  • If lockouts continue, have a technician test the gas valve and combustion setup.