ATAG

ATAG Furnaces Error Codes

Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.

Advertisements
E0
The furnace does not start; the display shows E0 immediately after power-up.
Control Board Initialization Failure
E1
The furnace attempts to start but shuts down with E1, with no flame established.
Ignition Failure / No Flame Detected
E2
The furnace locks out with E2 shortly after ignition; the flame appears unstable or goes out.
Flame Loss During Operation
E3
The furnace displays E3 and will not start the fan or ignition sequence.
Fan / Air Pressure Switch Fault
E4
The furnace shows E4 and shuts down, often after running for a short time.
Overheat / Safety Thermostat Trip
E5
Furnace displays E5 and will not fire, often accompanied by low or zero system pressure.
Low Water Pressure / Water Pressure Sensor Fault
E6
Furnace shows E6 and stops, often during hot water or heating demand.
Flow Temperature Sensor Fault
E7
Furnace displays E7, often with erratic temperature readings or short-cycling.
Return Temperature Sensor Fault
E8
Furnace shows E8 and will not start; the fan may run briefly then stop.
Flue Gas Temperature Sensor Fault / Overtemperature
E9
Furnace locks out with E9, often after several failed ignition attempts.
Lockout Due to Repeated Ignition Failure
EA
Furnace shows EA; the fan runs but there is no ignition, often associated with air pressure issues.
Air Pressure Switch Not Proving
EC
Furnace displays EC and stops, often during operation rather than at start-up.
Flame Signal Error / Ionisation Fault
F0
Furnace shows F0, with no heating or hot water; the display may be blank or frozen.
User Interface / Display Communication Error
F1
Furnace shows F1 and will not start, often after a power surge or outage.
General Control Board Fault
F2
Furnace shows F2; the fan may run continuously or not at all.
Fan Speed / Tachometer Fault
F3
Furnace displays F3, often with erratic or implausible temperature readings.
Domestic Hot Water (DHW) Temperature Sensor Fault
F4
Furnace shows F4 and stops, often when switching between heating and hot water.
Diverter Valve Position Fault
F5
Furnace displays F5, heating output limited or no heating.
Flow Switch / Flow Sensor Fault
F6
Furnace shows F6, burner shuts down unexpectedly during operation.
Gas Valve Modulation Fault
F7
Furnace displays F7, often with noisy operation or kettling sounds.
Primary Heat Exchanger Temperature Differential Fault
F8
Furnace shows F8, no hot water even though heating may work.
DHW Flow Detection Fault
F9
Furnace displays F9, often with rapid cycling on and off.
Return Temperature Rise Too Fast
Symptom
Condensate water backs up or drips from the furnace casing
Blocked Condensate Trap or Drain
Symptom
External flue terminal drips excessively or stains the wall
Condensate Management / Flue Installation Issue
Symptom
Furnace cycles on and off frequently without maintaining steady temperature
Short Cycling
Symptom
Furnace emits a burning smell or plastic smell during operation
Overheating Electrical Component or Dust Burn-Off
Symptom
Furnace fan runs but burner does not light, no error code displayed
Intermittent Ignition Control Fault
Symptom
Furnace frequently loses pressure and needs topping up.
Chronic System Pressure Loss
Symptom
Furnace is very noisy during operation (whistling, roaring, or droning)
Combustion or Fan Noise
Symptom
Furnace leaks water from the bottom of the casing
Internal Water Leak
Symptom
Furnace makes banging or knocking noises when starting or stopping
Water Hammer / Thermal Expansion Noise
Symptom
Furnace runs but radiators stay cold or only lukewarm.
Poor Heating Performance / Insufficient Flow
Symptom
Furnace shuts down when wind is strong, sometimes with no stored code
Flue Terminal Wind Effect / Combustion Instability
Symptom
Furnace starts then shuts down after a few seconds, radiators only warm at the top
Air in System / Poor Circulation
Symptom
Furnace will not start at all, no display, no lights.
No Power to Appliance
Symptom
Hot water temperature fluctuates or runs hot then cold
Unstable DHW Temperature Control
Symptom
Radiators get hot even when the room thermostat is turned down or off
Uncontrolled Heating / Valve Stuck Open
Symptom
Room thermostat or ATAG controller calls for heat but furnace does not respond
Control Signal / Communication Fault