STEADY ON
Concord
Normal Operation or Idle (No Fault)
The status LED on the Concord furnace is solid ON with no flashing; the furnace may or may not operate.
Advertisements
Possible Causes
No call for heat from the thermostat, Thermostat set to OFF or satisfied, Control board in standby mode, Blower running in fan-only mode
How to Fix / Troubleshooting
Note: A steady ON LED on many Concord furnace control boards indicates normal operation or standby, not a fault.
Checks:
- Thermostat settings: Ensure the thermostat is set to HEAT and the setpoint is above room temperature. Replace thermostat batteries if applicable.
- Call for heat at board: Check for 24 VAC between R and W terminals at the furnace control board when there is a call for heat. If no voltage, the issue is upstream (thermostat or wiring).
- Fan-only mode: If the blower is running but there is no heat and the LED is steady, the thermostat fan switch may be set to ON instead of AUTO.
Action: Correct thermostat settings or wiring as needed. No part replacement is required if the furnace operates normally when called.
Advertisements
Repair Difficulty
Very Easy
1/5