E7
Nibe Condensate drainage fault

E7 alarm: condensate level high or condensate pump fault; unit may shut down.

Advertisements

Possible Causes

Blocked condensate trap, failed condensate pump, kinked drain hose, or frozen condensate outlet.

How to Fix / Troubleshooting

Safety: Isolate power before working on the condensate pump. Condensate may be mildly acidic.

  • Check drain hose: Ensure the condensate hose from the Nibe unit to the drain is not kinked, blocked, or frozen.
  • Clean trap: Remove and clean the condensate trap and any filters. Flush with clean water.
  • Test pump: If a condensate pump is fitted, pour water into the pump reservoir and see if it activates (with power on). If not, check its power supply.
  • Reset alarm: After restoring drainage, reset the E7 alarm.

Replace the condensate pump if it fails to run despite correct power.