E22
Remeha
Return temperature too high / insufficient heat dissipation
The furnace shows E22; the burner stops and restarts frequently.
Advertisements
Possible Causes
Oversized furnace for system, low system flow rate, closed thermostatic radiator valves, incorrect pump speed setting.
How to Fix / Troubleshooting
Safety first: Surfaces may be hot. Isolate power before adjusting internal components.
- Open radiators: Ensure that enough radiators or heating circuits are open to dissipate the furnace output. Avoid closing all TRVs in the property.
- Check pump settings: On models with adjustable pump speed, set the pump to a higher speed to increase flow.
- Hydraulic balancing: Have a technician balance the system to ensure even flow through all circuits.
- Adjust maximum output: In the installer menu, reduce the maximum central heating output to better match the system load.
- Monitor operation: After adjustments, observe whether E22 and short cycling are reduced.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Circulation Pump
Check Price on Amazon
We may earn a commission from links on this page.