E22
Remeha Return temperature too high / insufficient heat dissipation

The furnace shows E22; the burner stops and restarts frequently.

Advertisements

Possible Causes

Oversized furnace for system, low system flow rate, closed thermostatic radiator valves, incorrect pump speed setting.

How to Fix / Troubleshooting

Safety first: Surfaces may be hot. Isolate power before adjusting internal components.

  • Open radiators: Ensure that enough radiators or heating circuits are open to dissipate the furnace output. Avoid closing all TRVs in the property.
  • Check pump settings: On models with adjustable pump speed, set the pump to a higher speed to increase flow.
  • Hydraulic balancing: Have a technician balance the system to ensure even flow through all circuits.
  • Adjust maximum output: In the installer menu, reduce the maximum central heating output to better match the system load.
  • Monitor operation: After adjustments, observe whether E22 and short cycling are reduced.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Circulation Pump
Check Price on Amazon

We may earn a commission from links on this page.