F.22
Vaillant Low Water Pressure / Dry Fire Protection

Display shows F.22, boiler will not fire, and the pressure gauge reads very low or zero.

Advertisements

Possible Causes

System pressure below minimum, leak in heating circuit, faulty pressure sensor, air in system causing a false low pressure reading.

How to Fix / Troubleshooting

Safety: Ensure the system is cool before adding water. Do not over-pressurize the system.

Refill procedure:

  • Locate the filling loop (flexible hose or integrated filling device) beneath the Vaillant boiler.
  • Check the current pressure on the gauge; if below approximately 0.8 bar, slowly open the filling valves.
  • Watch the gauge and close the valves when pressure reaches the recommended cold pressure (usually 1.0–1.5 bar; check the data plate/manual).
  • Bleed air from radiators, starting from the lowest to the highest, then recheck pressure and top up if needed.
  • Reset the boiler and check for normal operation.

If F.22 returns:

  • Inspect visible pipework, radiators, and the boiler underside for leaks.
  • If pressure drops repeatedly, a hidden leak or faulty expansion vessel may be present.
  • If pressure is normal but F.22 still displays, the water pressure sensor on the hydraulic block may be faulty and require replacement.

Call a professional if you suspect internal leaks, expansion vessel failure, or if you are unsure how to safely use the filling loop.