Aprilaire
Over-Humidification / Control Misadjustment.
Aprilaire humidifier causes condensation on windows and walls.
Advertisements
Possible Causes
Humidity setpoint too high for outdoor temperature, outdoor sensor not connected in automatic mode, humidistat located in a poor location, control bypassed or miswired.
How to Fix / Troubleshooting
Safety first: No internal electrical work is required for basic adjustments.
- Lower setpoint: Reduce the humidity setting according to outdoor temperature (e.g., 30–35% when below freezing outside).
- Enable automatic mode: If using an Aprilaire automatic control, ensure the outdoor temperature sensor is connected and the control is set to Automatic mode so it can adjust humidity based on outdoor conditions.
- Relocate humidistat: If the control is in a damp area (kitchen, bathroom), relocate it to a representative location or use a return-duct-mounted sensor.
- Check wiring: Verify the humidifier is not wired to run continuously regardless of control (no permanent jumper across control terminals).
Advertisements
Repair Difficulty
Easy