E4
Aprilaire Low Temperature / Coil Freeze Protection Fault

Aprilaire dehumidifier displays E4, and it will not start the compressor.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Operating in a space below the recommended temperature, restricted airflow across the coil, failed coil temperature sensor, low refrigerant charge causing coil freeze.

How to Fix / Troubleshooting

Safety first: Turn off power before inspecting internal components.

  • Verify ambient temperature: Check the room or crawlspace temperature. Most Aprilaire dehumidifiers require ambient temperatures above about 50°F (10°C). If the space is too cold, relocate the unit or add supplemental heat.
  • Check airflow: Ensure that filters and grilles are clean and unobstructed. Restricted airflow can cause the coil to freeze and trigger E4.
  • Inspect coil: Remove the access panel and look for ice buildup on the evaporator coil. If present, leave the unit off until all ice melts and correct airflow issues.
  • Check coil sensor: Confirm that the coil temperature sensor is firmly attached to the coil and that the wiring is intact. Replace the Aprilaire coil temperature sensor if it reads out of range.
  • Professional diagnosis: If E4 recurs with proper temperature and airflow, a refrigerant problem may exist. Have an HVAC technician evaluate the sealed system.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Aprilaire Coil Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements