F1
Midea
Keypad / Control Panel Fault
Dehumidifier displays F1 and does not respond to controls properly.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck or shorted keypad button, Moisture intrusion into control panel, Damaged control panel PCB, Loose ribbon cable between keypad and main board
How to Fix / Troubleshooting
Safety: Unplug the unit before working on the control panel.
- Dry the panel: If the panel is damp from cleaning or condensation, allow it to dry completely for several hours with the unit unplugged.
- Inspect buttons: Check for physically stuck buttons. Gently work them to free any that are jammed.
- Open control panel: Remove screws securing the top/front bezel and carefully lift off to expose the keypad PCB and ribbon cable.
- Reseat ribbon cable: Disconnect and reconnect the cable between the keypad and main board, ensuring it is fully inserted and locked.
- Clean contacts: If corrosion is visible, lightly clean with isopropyl alcohol and a soft brush, then let dry.
- Replace control panel PCB: If F1 persists, replace the "Midea control panel / keypad board" for your model.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Control Panel / Keypad PCB
Check Price on Amazon