P3
Midea Low Temperature Protection / Anti-Freeze Mode

The dehumidifier displays P3 and the compressor does not start; however, the fan may continue to run.

Advertisements

Possible Causes

Room temperature below operating range, faulty ambient temperature sensor reading too low, unit placed near a cold draft or on a cold floor, control board misinterpreting temperature.

How to Fix / Troubleshooting

Note: P3 often indicates the unit is protecting itself from operating in too cold an environment.

  • Check room temperature: Use a thermometer to verify the room is above the minimum operating temperature (typically 41°F / 5°C). If not, move the unit to a warmer location.
  • Avoid cold drafts: Do not place the dehumidifier directly on a cold concrete floor or near open windows in winter. Elevate it slightly and keep away from cold walls.
  • Reset: Unplug the unit for 5 minutes, then plug back in and test in a warmer area.
  • If P3 persists in a warm room: The ambient temperature sensor may be faulty or mispositioned. See the E1 entry for sensor testing and replacement steps.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Ambient Temperature Sensor (NTC)
Check Price on Amazon

We may earn a commission from links on this page.