E6
Avanti Ice Thickness Sensor / Probe Fault

Avanti ice maker displays E6 and stops; the unit may fill with water but does not freeze or harvest properly.

Advertisements

Possible Causes

Dirty or scaled ice thickness probe, misaligned thickness sensor, broken sensor wiring, or a failed ice thickness control board circuit.

How to Fix / Troubleshooting

Safety: Unplug the unit before reaching into the ice-making compartment.

Steps to resolve:

  • 1. Locate the ice thickness probe: On many Avanti models, a metal or plastic probe or sensor arm sits near the evaporator plate or ice grid to measure ice thickness.
  • 2. Clean the probe: Mineral scale or slime on the probe can cause incorrect readings. Clean it with a soft cloth and a solution of warm water and ice maker cleaner or white vinegar. Rinse with clean water and dry.
  • 3. Check alignment: Ensure the probe is positioned according to the user manual, typically just touching or slightly away from the ice surface when fully formed. Gently adjust if bent.
  • 4. Inspect wiring: Follow the probe wires back to the control board. Look for breaks, pinches, or loose connectors. Reseat the connector on the board.
  • 5. Test operation: Restore power and run a cycle. If E6 returns after cleaning and inspection, the sensor or control board may need replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Ice Thickness Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements