E6
Avanti Ice Thickness Sensor / Probe Fault

Avanti ice maker displays E6 and stops; unit may fill with water but does not freeze or harvest properly.

Advertisements

Possible Causes

Dirty or scaled ice thickness probe, misaligned thickness sensor, broken sensor wiring, failed ice thickness control board circuit

How to Fix / Troubleshooting

Safety: Unplug the unit before reaching into the ice-making compartment.

Steps to resolve:

  • 1. Locate the ice thickness probe: On many Avanti models, a metal or plastic probe or sensor arm sits near the evaporator plate or ice grid to measure ice thickness.
  • 2. Clean the probe: Mineral scale or slime on the probe can cause incorrect readings. Clean it with a soft cloth and a solution of warm water and ice maker cleaner or white vinegar. Rinse with clean water and dry.
  • 3. Check alignment: Ensure the probe is positioned according to the user manual, typically just touching or slightly away from the ice surface when fully formed. Gently adjust if bent.
  • 4. Inspect wiring: Follow the probe wires back to the control board. Look for breaks, pinches, or loose connectors. Reseat the connector on the board.
  • 5. Test operation: Restore power and run a cycle. If E6 returns after cleaning and inspection, the sensor or control board may need replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Ice Thickness Sensor
Check Price on Amazon

We may earn a commission from links on this page.