E12 is displayed; the unit may not fill with water or may overfill.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: Turn off the power and close the water supply valve. Have towels ready for any residual water.
Steps:
- Check the water supply: Verify that the shutoff valve is fully open and that there are no kinks in the supply line. Confirm adequate water pressure.
- Clean the inlet screen: Disconnect the water line at the inlet valve on the Manitowoc unit. Remove and clean the small screen filter inside the valve using a brush and water.
- Test the valve coil: With a multimeter, check the resistance of the water inlet valve coil. An open coil indicates a failed valve that must be replaced.
- Observe fill behavior: After reassembly and restoring power, watch the fill cycle. If the valve does not open or does not shut off, replace the water inlet valve.
Note: If the valve is working but the machine still misreads the water level, inspect the water level probe or sensor as well.