E19
Teka
Door Switch / Bin Door Sensor Fault
E19 error: The unit indicates the door or bin is open even when it is closed.
Advertisements
Possible Causes
Defective door switch, Misaligned door magnet and reed sensor, Broken switch actuator, Loose wiring to the control board
How to Fix / Troubleshooting
Safety first: Disconnect power before working around door switches.
- Inspect door alignment: Ensure the ice bin door closes fully and is not obstructed by ice or foreign objects.
- Check switch or magnet: Locate the door switch or magnetic sensor. Verify that the actuator or magnet lines up correctly when the door is closed. Adjust mounting screws if needed.
- Test switch: Use a multimeter to check the continuity of the door switch while opening and closing the door. Replace the switch if it does not change state reliably.
- Inspect wiring: Follow the switch wires to the control board, checking for breaks or loose connectors. Repair as necessary.
- Reset and test: Restore power and confirm that the E19 error clears when the door is closed and that the unit resumes operation.
Advertisements
Repair Difficulty
Easy
2/5