E1
Fisher & Paykel
Communication Error Between Control and User Interface
Microwave displays E1 and will not start or certain functions are disabled.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose harness between display board and main control, Corroded connectors on UI board, Failed user interface PCB, Faulty main control PCB
How to Fix / Troubleshooting
Safety first: Unplug the microwave before removing the control panel.
- Power reset: Disconnect power for 5–10 minutes, then reconnect. If E1 clears temporarily, an intermittent connection is likely.
- Access control area: Remove the top grille and control panel to expose the user interface and main control boards.
- Check harness connections: Reseat all multi-pin connectors between the UI/display board and the main control PCB. Ensure they are fully engaged and locked.
- Inspect for corrosion or damage: Look for signs of moisture, corrosion, or burned components on both boards. Clean light corrosion with isopropyl alcohol.
- Board replacement: If E1 persists, determine whether the UI or main control is at fault (service manual may provide diagnostic steps). Replace the defective board with the correct Fisher & Paykel part.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
User Interface PCB
Check Price on Amazon
We may earn a commission from links on this page.