Possible Causes

Worn or damaged steam release valve gasket, Food residue lodged in valve seat, Bent or misaligned valve stem, Weak valve spring (if spring-loaded design)

How to Fix / Troubleshooting

Safety first: Turn off and unplug the cooker. Allow pressure to drop naturally before removing the valve.

  • 1. Remove valve: Lift or unscrew the steam release valve from the lid (depending on model).
  • 2. Clean thoroughly: Soak the valve in warm soapy water and use a small brush to remove residue from the internal passages and seat.
  • 3. Inspect gasket and stem: Check the underside gasket or O-ring for cracks or flattening. Ensure the stem is straight and moves freely.
  • 4. Replace if worn: Install a new Chefman-compatible steam release valve or gasket if any damage is found.
  • 5. Re-test: Reinstall the valve, set to Sealing, and run a water-only pressure test to confirm proper sealing.