E04
Toshiba Cavity Sensor Open/Short Error

Oven display shows an over-temperature or sensor error shortly after starting; heating stops and cooling fan may run.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open-circuit temperature sensor, Shorted temperature sensor, Corroded sensor connector, Faulty sensor input on control PCB

How to Fix / Troubleshooting

Safety first: Isolate the oven from power before accessing internal components.

  • Locate and test sensor: Remove the rear cover to access the Toshiba cavity sensor connector. Disconnect and measure resistance at room temperature. If it reads OL (open) or near 0 Ω (short), replace the sensor.
  • Check connector and harness: Inspect the plug and socket for corrosion or moisture ingress. Clean with contact cleaner and ensure a tight fit. Check the harness for breaks or crushed sections.
  • Simulate sensor (advanced): If you have the correct resistor value from Toshiba service data, you can temporarily connect a fixed resistor to the PCB sensor input to confirm the board reads a stable temperature. If the error persists with a known-good resistor, the control PCB is likely faulty.
  • Replace control PCB if needed: If sensor and wiring are confirmed good, replace the Toshiba oven control module.

Do not bypass or short the sensor for normal operation; this is unsafe and can cause overheating.