Aquacomfort
Silent Ignition Failure
Heater fan runs but burners do not light; no error code is shown.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Weak igniter, Dirty flame sensor, Gas valve not opening, Air in gas line after service
How to Fix / Troubleshooting
Safety first: Turn off gas and power before removing burner or ignition components.
- Observe through sight glass: Call for heat and watch for igniter glow or spark. If there is no glow/spark, the igniter or control board may be faulty.
- Clean igniter/flame sensor: Gently clean the igniter and flame sensor surfaces with fine emery cloth and reinstall.
- Gas supply check: Ensure the gas shutoff valve is fully open. If gas service was recently interrupted, there may be air in the line; a technician should safely purge and test.
- Professional diagnosis: If the fan runs but there is no ignition and no code, a technician should test the gas valve and control outputs.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Igniter and Flame Sensor Assembly