Possible Causes

Open safety circuit (pressure switch, high limit, rollout), Faulty SmartPool control board logic, Loose safety loop wiring

How to Fix / Troubleshooting

Overview: The control will not open the gas valve until all safety devices are confirmed closed.

  • Check display: Check the display for any small icons or text indicating open safety devices (FLO, HI, ROL), even if no error code is shown.
  • Inspect safety loop: With power off, trace the low-voltage safety circuit wiring (pressure switch, high limit, rollout) and ensure all connectors are secure.
  • Reset manual safeties: If your SmartPool model has manual reset high limit or rollout switches, press them once after the heater has cooled down.
  • Test again: Restore power and call for heat. If there is still no ignition sequence, the control board may not be detecting the safety loop as closed.