Pump display shows E12 and the motor will not start; may occur after a lightning storm or grid disturbance.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: Only qualified personnel should measure live voltages. Turn off power before opening covers.
- Measure supply voltage: Using a multimeter, verify that the line voltage at the pump matches the rating on the Emaux nameplate and is not exceeding it by more than 10%.
- Check neutral integrity: Ensure the neutral conductor is securely connected and not shared improperly with other circuits.
- Install surge protection: If not already present, have an electrician install surge protection at the pool equipment subpanel.
- Reset and test: After correcting any supply issues, power cycle the pump and attempt to restart.
If E12 remains with correct voltage, the input stage of the inverter/control PCB is likely damaged and the module should be replaced.