E11
Lowara
External Control Signal Fault (Analog/Digital Input Error)
Pump display shows E11, runs only at fixed speed or not at all under external control
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Broken 0–10 V or 4–20 mA control cable, Incorrect control signal polarity, Misconfigured input type in Lowara drive, Faulty external controller (pool automation system)
How to Fix / Troubleshooting
Safety first: Isolate power to the control circuits before working on low‑voltage wiring.
- Check control wiring: Verify that the analog or digital control wires are connected to the correct terminals on the Lowara drive as per the wiring diagram. Tighten any loose screws.
- Measure control signal: With the external controller commanding run, measure the signal (e.g. 0–10 V) at the drive input. Confirm it is within the expected range.
- Verify configuration: Enter the drive’s parameter menu and ensure the control input type (voltage/current/digital) matches the external controller output.
- Test local mode: Switch the drive to local/manual mode and start the pump from the keypad. If it runs normally, the issue is with the external control circuit.
- When to call a pro: If E11 persists with correct wiring and signal, the input circuitry on the drive PCB may be damaged and require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Lowara drive control input terminals / PCB