E07
Brandt
Control Board Communication Error
Induction cooktop shows E07 and does not respond to touch commands.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose communication harness between touch panel and main board, Faulty main control board, Faulty user interface board, Electrical noise or surge damage
How to Fix / Troubleshooting
Safety first: Isolate the appliance from mains before opening the housing.
Steps:
- Power cycle: Turn off the breaker for 10 minutes, then restore power. Sometimes communication errors clear after a full reset.
- Inspect wiring: Remove the hob and access the control area. Check all low-voltage connectors between the touch panel, main control board, and power modules. Reseat each connector firmly.
- Look for corrosion or moisture: Any signs of liquid ingress on the control boards can cause intermittent communication faults. Dry the area thoroughly and clean with appropriate electronics cleaner if minor.
- Check for visible damage: Burn marks or swollen components on the control board indicate surge damage; the board must be replaced.
- Replace defective board: If wiring is intact and E07 persists, replace the main control board or user interface board as per Brandt service documentation.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Control Board
Check Price on Amazon
We may earn a commission from links on this page.