E2
Neff Ignition System Fault / Spark Generator Error

Gas hob with electronic ignition shows E2 on the display (if equipped) and ignition stops working.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty spark generator module, Moisture around burner caps and electrodes, Loose ignition electrode connection, Damaged ignition switch in control knob

How to Fix / Troubleshooting

Gas safety: If you smell gas, turn off the gas supply immediately, ventilate the room, and do not use electrical switches or open flames. Contact a gas professional.

  • Dry the hob: If there has been a spill or cleaning, moisture may be shorting the ignition. Turn off power, remove burner caps, and dry the area thoroughly with a cloth. Allow several hours to air dry.
  • Check burner assembly: Ensure burner caps and rings are correctly seated. Misalignment can prevent proper sparking.
  • Test ignition: Restore power and turn a knob to the ignition position. Look for a visible spark at the electrode.
  • If no spark and E2 remains: The spark generator module or ignition switches may be faulty. Replacement should be carried out by a qualified technician due to gas and mains voltage involvement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Spark Generator Module
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements