F11
Bauknecht Door Switch or Door Sensor Fault

Door open alarm sounds even when all doors are properly closed

Advertisements

Possible Causes

Defective magnetic door switch, Misaligned door, Broken or loose door switch wiring, Faulty reed sensor on control board

How to Fix / Troubleshooting

Safety first: Unplug the refrigerator before removing door switch components.

  • Check door alignment: Ensure the door closes fully and evenly. Look for items inside that may be preventing full closure.
  • Inspect gasket: Check the door gasket for warping or debris that could keep the door slightly open.
  • Test door switch: Locate the door switch (usually at the top or side of the compartment). Press it manually; the interior light should turn off and the alarm should stop. If not, the switch may be faulty.
  • Check magnetic sensor (if applicable): Some models use a magnet in the door and a reed sensor in the frame. Ensure the magnet is present and not loose.
  • Replace faulty switch: Pry out or unscrew the switch, disconnect the wires, and install a new compatible switch, reconnecting wires as originally.
  • Re-test: Restore power and verify that the alarm stops when the door is closed.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements