E10
Gaggenau Door Switch / Door Contact Fault

Refrigerator displays E10 and may show issues with door alarm or interior lights not responding correctly to door position.

Advertisements

Possible Causes

Defective magnetic reed switch or mechanical door switch, Misaligned door magnet, Broken wiring in door harness, Faulty input circuit on main control board

How to Fix / Troubleshooting

Safety: Disconnect power before removing door switch components or trim.

Steps:

  • 1. Check door operation: Open and close the door while observing the interior light and door-open icon on the display. If the light stays on or off incorrectly, the switch may be faulty.
  • 2. Identify switch type: Gaggenau models may use a mechanical plunger switch in the frame or a magnetic reed switch with a magnet in the door. Locate the switch or sensor area.
  • 3. Inspect for damage or misalignment: Ensure the door closes fully and the magnet (if used) aligns with the sensor. Adjust door hinges if necessary.
  • 4. Test the switch: Remove the switch or access the sensor wiring. With power off, check continuity while operating the switch or moving a magnet near the reed sensor. Replace if it does not change state.
  • 5. Check wiring: Inspect the harness for breaks, especially in the hinge area where wires flex. Repair or replace damaged wiring.
  • 6. Replace faulty components: Install a new door switch or reed sensor as required. Ensure it is firmly seated and aligned.

Note: If the switch and wiring are good but E10 persists, the main control board may not be reading the input correctly and may need replacement by a technician.

Advertisements

Video Guide

Repair Difficulty

Easy 2/5

Required Part

Door Switch / Reed Sensor