LG Refrigerators Error Codes
Complete list of fault codes and troubleshooting guides. Use the search below to find your specific error.
Advertisements
Er 0F
Error code “0F” or “OF” is displayed, and the refrigerator is in demo mode; cooling is off but lights and display work.
Demo Mode Activated
Er 1C
Error code “1C” or “IC” is displayed, and ice production stops; sometimes accompanied by water in the ice room.
Ice Maker Sensor or Communication Error
Er 1F
Error code “Er 1F” and ice production stops; often associated with ice room fan issues.
Ice Room Fan Motor or Feedback Fault
Er 22
Error code “Er 22” and the refrigerator may not cool; compressor may not start.
Compressor Relay / Inverter PCB Error
Er 2F
Error code “2F” is displayed, the fresh food section may be too warm, and airflow from vents is weak.
Refrigerator Fan or Duct Damper Error
Er 5C
Error code “5C” or “SC” is displayed, and the water dispenser or ice maker may not function correctly.
Water Circuit or Sensor Error
Er 5Y
Error code similar to “5Y” or “SY” is displayed, and cooling performance is unstable.
Sensor or PCB Interpretation Error
Er 67
Error code “Er 67” and doors may not close properly; cooling performance may be poor.
Door Open / Door Switch or Door Alignment Error
Er 88 88
Display shows “88 88” or all segments are lit; refrigerator may not respond to controls.
Control Panel Initialization / Power-On Self-Test Error
Er CF
Error code “Er CF” and the refrigerator may not cool properly; condenser fan at the back may not run.
Condenser Fan Motor Failure
Er CO
Error code “Er CO” appears and some functions may be disabled; display may be unresponsive.
Communication Error Between Main PCB and Display PCB
Er dF
Error code “Er dF” and intermittent cooling; frost may appear on back wall of freezer.
Defrost Function Error / Incomplete Defrost
Er dH
Error code “Er dH” and heavy frost buildup on the evaporator; refrigerator may be warm.
Defrost Heater or Defrost Circuit Failure
Er dS
Display shows “Er dS” and refrigerator may not cool properly or may run continuously.
Defrost Sensor / Evaporator Thermistor Fault
Er F dH
Error code related to “F dH” or “F DH” and freezer section shows heavy frost; cooling is poor.
Freezer Defrost Heater Failure
Er F dS
Error code “F dS” or similar and freezer temperature reading is erratic; frost issues may occur.
Freezer Defrost Sensor (Thermistor) Error
Er FF
Error code “Er FF” and freezer temperature is too warm or fluctuates; compressor may run continuously.
Freezer Fan Motor Failure
Er FS
Freezer sensor error displayed as “Er FS” and freezer temperature reading is inaccurate or dashes appear.
Freezer Temperature Sensor (Thermistor) Fault
Er HS
Error code “Er HS” appears and the unit may not defrost correctly or may show erratic temperature behavior.
Humidity Sensor / Defrost Humidity Sensor Fault
Er IF
Error code “Er IF” and ice production is poor or non-existent; sometimes a clicking noise from the ice compartment.
Ice Maker Fan Motor Failure
Er IS
Error code “Er IS” and ice production stops or is severely reduced.
Ice Room / Ice Maker Fan or Sensor Fault
Er rF
Error code “Er rF” is displayed, the fresh food section is warm, and there is little or no airflow from the vents.
Refrigerator Evaporator Fan Motor Failure
Er rF dH
Combined refrigerator fan/defrost error; fresh food section may ice up and fan may be noisy or stop.
Refrigerator Evaporator Fan and Defrost System Fault
Er rS
Refrigerator sensor error “Er rS” and fresh food temperature display is incorrect or shows dashes.
Refrigerator Compartment Temperature Sensor Fault
Er SS
Error code “Er SS” is displayed, temperature readings may be inaccurate, and cooling may be erratic.
Shorted Temperature Sensor
Symptom
A bad odor persists inside the refrigerator even after removing spoiled food.
Persistent Odor / Airflow and Drain Contamination
Symptom
Clicking noise and the refrigerator is not cooling; the compressor attempts to start repeatedly.
Compressor Start Failure
Symptom
Condensation or moisture is forming on the door gaskets and around the dispenser area.
Door Heater / Mullion Heater or Gasket Condensation
Symptom
Freezer is cold but the refrigerator is warm; little or no air is coming from the refrigerator vents.
Refrigerator Airflow / Evaporator Fan or Duct Blockage
Symptom
Ice buildup on the back wall of the freezer; freezer temperature rises over time and the fan becomes noisy.
Defrost System Failure
Symptom
Loud buzzing or humming noise from the back of the refrigerator, especially when the compressor runs.
Condenser Fan or Compressor Noise
Symptom
Rattling or vibrating noise, especially when the compressor starts or stops.
Cabinet Vibration / Loose Components
Symptom
Refrigerator is not cooling at all; both refrigerator and freezer are warm, interior lights work, but fans may or may not run.
No Cooling / Sealed System or Compressor Failure
Symptom
Refrigerator runs constantly and is too cold or too warm; temperature does not match the setpoint.
Temperature Regulation / Thermistor or Control Calibration Issue
Symptom
The display panel is unresponsive. It's not possible to change the temperature or modes, but the appliance continues to cool.
User Interface / Touch Panel Failure
Symptom
The doors are not closing properly or are popping open, leading to warm air intrusion and frost buildup inside.
Door Alignment and Gasket Seal Issue
Symptom
The ice maker is not making ice; the ice bin is empty after 24–48 hours.
Ice Production Failure
Symptom
The ice maker makes ice but does not dispense; the auger motor runs or hums but ice does not come out.
Ice Dispensing Mechanism Failure
Symptom
The interior lights are not working, but the refrigerator is still cooling normally.
Lighting Circuit Failure
Symptom
The refrigerator periodically makes a gurgling or hissing sound.
Normal Refrigerant Flow Noise
Symptom
The water dispenser is not working. There is no water flow, although the icemaker may still be producing ice.
Dispenser Water Flow Failure
Symptom
Water is leaking from the front bottom of the refrigerator onto the floor.
Drain System or Water Line Leak
Symptom
Water is leaking inside the refrigerator, pooling under the crisper drawers.
Blocked Defrost Drain in Fresh Food Section
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| Er 0F |
Error code “0F” or “OF” is displayed, and the refrigerator is in demo mode; cooling is off but lights and display work.
|
Demo Mode Activated | View Details |
| Er 1C |
Error code “1C” or “IC” is displayed, and ice production stops; sometimes accompanied by water in the ice room.
|
Ice Maker Sensor or Communication Error | View Details |
| Er 1F |
Error code “Er 1F” and ice production stops; often associated with ice room fan issues.
|
Ice Room Fan Motor or Feedback Fault | View Details |
| Er 22 |
Error code “Er 22” and the refrigerator may not cool; compressor may not start.
|
Compressor Relay / Inverter PCB Error | View Details |
| Er 2F |
Error code “2F” is displayed, the fresh food section may be too warm, and airflow from vents is weak.
|
Refrigerator Fan or Duct Damper Error | View Details |
| Er 5C |
Error code “5C” or “SC” is displayed, and the water dispenser or ice maker may not function correctly.
|
Water Circuit or Sensor Error | View Details |
| Er 5Y |
Error code similar to “5Y” or “SY” is displayed, and cooling performance is unstable.
|
Sensor or PCB Interpretation Error | View Details |
| Er 67 |
Error code “Er 67” and doors may not close properly; cooling performance may be poor.
|
Door Open / Door Switch or Door Alignment Error | View Details |
| Er 88 88 |
Display shows “88 88” or all segments are lit; refrigerator may not respond to controls.
|
Control Panel Initialization / Power-On Self-Test Error | View Details |
| Er CF |
Error code “Er CF” and the refrigerator may not cool properly; condenser fan at the back may not run.
|
Condenser Fan Motor Failure | View Details |
| Er CO |
Error code “Er CO” appears and some functions may be disabled; display may be unresponsive.
|
Communication Error Between Main PCB and Display PCB | View Details |
| Er dF |
Error code “Er dF” and intermittent cooling; frost may appear on back wall of freezer.
|
Defrost Function Error / Incomplete Defrost | View Details |
| Er dH |
Error code “Er dH” and heavy frost buildup on the evaporator; refrigerator may be warm.
|
Defrost Heater or Defrost Circuit Failure | View Details |
| Er dS |
Display shows “Er dS” and refrigerator may not cool properly or may run continuously.
|
Defrost Sensor / Evaporator Thermistor Fault | View Details |
| Er F dH |
Error code related to “F dH” or “F DH” and freezer section shows heavy frost; cooling is poor.
|
Freezer Defrost Heater Failure | View Details |
| Er F dS |
Error code “F dS” or similar and freezer temperature reading is erratic; frost issues may occur.
|
Freezer Defrost Sensor (Thermistor) Error | View Details |
| Er FF |
Error code “Er FF” and freezer temperature is too warm or fluctuates; compressor may run continuously.
|
Freezer Fan Motor Failure | View Details |
| Er FS |
Freezer sensor error displayed as “Er FS” and freezer temperature reading is inaccurate or dashes appear.
|
Freezer Temperature Sensor (Thermistor) Fault | View Details |
| Er HS |
Error code “Er HS” appears and the unit may not defrost correctly or may show erratic temperature behavior.
|
Humidity Sensor / Defrost Humidity Sensor Fault | View Details |
| Er IF |
Error code “Er IF” and ice production is poor or non-existent; sometimes a clicking noise from the ice compartment.
|
Ice Maker Fan Motor Failure | View Details |
| Er IS |
Error code “Er IS” and ice production stops or is severely reduced.
|
Ice Room / Ice Maker Fan or Sensor Fault | View Details |
| Er rF |
Error code “Er rF” is displayed, the fresh food section is warm, and there is little or no airflow from the vents.
|
Refrigerator Evaporator Fan Motor Failure | View Details |
| Er rF dH |
Combined refrigerator fan/defrost error; fresh food section may ice up and fan may be noisy or stop.
|
Refrigerator Evaporator Fan and Defrost System Fault | View Details |
| Er rS |
Refrigerator sensor error “Er rS” and fresh food temperature display is incorrect or shows dashes.
|
Refrigerator Compartment Temperature Sensor Fault | View Details |
| Er SS |
Error code “Er SS” is displayed, temperature readings may be inaccurate, and cooling may be erratic.
|
Shorted Temperature Sensor | View Details |
| – |
A bad odor persists inside the refrigerator even after removing spoiled food.
|
Persistent Odor / Airflow and Drain Contamination | View Details |
| – |
Clicking noise and the refrigerator is not cooling; the compressor attempts to start repeatedly.
|
Compressor Start Failure | View Details |
| – |
Condensation or moisture is forming on the door gaskets and around the dispenser area.
|
Door Heater / Mullion Heater or Gasket Condensation | View Details |
| – |
Freezer is cold but the refrigerator is warm; little or no air is coming from the refrigerator vents.
|
Refrigerator Airflow / Evaporator Fan or Duct Blockage | View Details |
| – |
Ice buildup on the back wall of the freezer; freezer temperature rises over time and the fan becomes noisy.
|
Defrost System Failure | View Details |
| – |
Loud buzzing or humming noise from the back of the refrigerator, especially when the compressor runs.
|
Condenser Fan or Compressor Noise | View Details |
| – |
Rattling or vibrating noise, especially when the compressor starts or stops.
|
Cabinet Vibration / Loose Components | View Details |
| – |
Refrigerator is not cooling at all; both refrigerator and freezer are warm, interior lights work, but fans may or may not run.
|
No Cooling / Sealed System or Compressor Failure | View Details |
| – |
Refrigerator runs constantly and is too cold or too warm; temperature does not match the setpoint.
|
Temperature Regulation / Thermistor or Control Calibration Issue | View Details |
| – |
The display panel is unresponsive. It's not possible to change the temperature or modes, but the appliance continues to cool.
|
User Interface / Touch Panel Failure | View Details |
| – |
The doors are not closing properly or are popping open, leading to warm air intrusion and frost buildup inside.
|
Door Alignment and Gasket Seal Issue | View Details |
| – |
The ice maker is not making ice; the ice bin is empty after 24–48 hours.
|
Ice Production Failure | View Details |
| – |
The ice maker makes ice but does not dispense; the auger motor runs or hums but ice does not come out.
|
Ice Dispensing Mechanism Failure | View Details |
| – |
The interior lights are not working, but the refrigerator is still cooling normally.
|
Lighting Circuit Failure | View Details |
| – |
The refrigerator periodically makes a gurgling or hissing sound.
|
Normal Refrigerant Flow Noise | View Details |
| – |
The water dispenser is not working. There is no water flow, although the icemaker may still be producing ice.
|
Dispenser Water Flow Failure | View Details |
| – |
Water is leaking from the front bottom of the refrigerator onto the floor.
|
Drain System or Water Line Leak | View Details |
| – |
Water is leaking inside the refrigerator, pooling under the crisper drawers.
|
Blocked Defrost Drain in Fresh Food Section | View Details |
No matching codes found
Advertisements