E16
Siemens
Door Switch / Reed Sensor Fault
E16 error is displayed. The interior lights may stay on or turn off incorrectly, and the door alarm may not function properly.
Advertisements
Possible Causes
Failed magnetic reed switch, Misaligned door magnet, Broken door switch wiring, Faulty input circuit on main PCB
How to Fix / Troubleshooting
Safety first: Unplug the refrigerator before removing any trims or switch housings.
Steps:
- 1. Locate door switch or sensor: Siemens refrigerators may use mechanical plunger switches or hidden magnetic reed sensors in the cabinet frame.
- 2. Test operation: For plunger switches, press the switch manually and listen for a click; check if lights respond when power is restored. For reed sensors, move a magnet near the sensor location and observe light behavior.
- 3. Inspect magnet alignment: Ensure the magnet in the door gasket or trim aligns with the sensor when the door is closed. Adjust gasket or trim if necessary.
- 4. Check wiring: Remove the switch housing and inspect wiring for breaks or loose connectors.
- 5. Replace faulty switch/sensor: Install a new Siemens-compatible door switch or reed sensor if defective.
Tip: A faulty door sensor can also cause temperature issues because the control may think the door is always open.