Guide 1 not found
Husqvarna Guide wire 1 signal missing

Display shows “Guide 1 not found,” and the mower has difficulty returning to the charging station via Guide 1.

Advertisements

Possible Causes

Broken Guide 1 wire, loose Guide 1 terminal connection, incorrect guide wire installation, or faulty station guide output.

How to Fix / Troubleshooting

Safety first: Disconnect the station power before handling wires.

  • Check terminal: Verify that the Guide 1 wire is firmly connected to the correct terminal on the charging station.
  • Inspect wire route: Walk along the Guide 1 path and look for damage from gardening tools, rodents, or ground movement.
  • Repair breaks: Use Husqvarna waterproof connectors to splice any damaged sections.
  • Test LED: After repair, restore power and confirm the station LED indicates a healthy loop.
  • Recalibrate guide: Use the mower’s guide calibration function if available.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Guide Wire 1
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements