Short Cycling / Incorrect Control Configuration
The thermostat or Wiser app shows heating on, but radiators are only lukewarm and the boiler cycles rapidly.
Advertisements
Possible Causes
Cycle rate set too high, minimum on-time too short, boiler anti-cycling conflicting with thermostat TPI, oversized boiler for the system.
How to Fix / Troubleshooting
Safety first: Control setting changes are low risk; do not open mains devices without isolating power.
- Adjust cycle rate: In the Drayton thermostat or Wiser app, set the cycle rate appropriate for your boiler type (e.g., 6 cycles/hour for gas boilers).
- Increase minimum on-time: Set a longer minimum on-time to reduce very short firing periods.
- Check boiler settings: Ensure boiler anti-cycling and flow temperature settings are compatible with TPI control. Consult the boiler manual.
- Observe performance: After adjustments, monitor for longer, more stable heating cycles and improved radiator temperature.