Vokera Temperature measurement inaccuracy/sensor misplacement.

The thermostat shows a much higher or lower room temperature than actual.

Advertisements

Possible Causes

Thermostat mounted on an external wall or above a radiator; internal NTC sensor drift; warm air from the boiler flue or pipes affecting the sensor; incorrect temperature offset setting.

How to Fix / Troubleshooting

Safety first: No special hazards.

  • Compare with a thermometer: Place a reliable thermometer near the thermostat and compare readings after 15–20 minutes.
  • Adjust offset: Use the thermostat's calibration/offset setting to correct small differences (e.g., ±1–2°C).
  • Relocate thermostat: If the thermostat is on an external wall, above a radiator, or near a heat source, move it to an internal wall in a representative room.
  • If a large error remains: The internal sensor may be faulty. Replace the thermostat or add a Vokera remote room sensor if supported.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Vokera smart thermostat internal temperature sensor.