COMM
Controller displays COMM or COMMS LOSS, and remote monitoring or ATS communication fails.
Communication Bus Fault
ESTOP
Controller displays ESTOP or EMERGENCY STOP, and the generator will not crank.
Emergency Stop Circuit Active
EXER
Controller displays EXER FAIL or EXERCISE FAILED after a scheduled exercise period.
Failed Exercise Run
HBT
The controller displays 'HBT' or 'HIGH BAT', and may shut down charging or log a fault.
High Battery Voltage Fault
HET
Controller displays HET or HIGH ENG TEMP, and the generator shuts down during or shortly after running.
High Engine Temperature Shutdown
HF
The controller displays 'HF', and the generator shuts down or refuses to transfer load.
Overfrequency / Engine Overspeed Fault
HOV
The controller displays 'HOV', and the generator shuts down or drops load.
High Output Voltage Fault
IGN
Controller displays IGN or IGNITION FAULT, and the generator cranks but does not start.
Ignition System Failure
LOAC
Controller displays LOAC or NO AC, and the generator runs but the transfer switch does not transfer the load.
Loss of AC Sensing / No Output Detected by Controller
LOBT
The controller displays 'LOBT' or 'LOW BAT', and the generator will not crank or cranks slowly.
Low Battery Voltage Fault
LOF
Controller displays LOF, and the generator shuts down or will not start.
Loss of Frequency / Loss of Engine Speed Signal
LOFUEL
Controller displays LO FUEL or LOW FUEL (LP tank models), and the generator will not run a full cycle.
Low Fuel Level / Fuel Supply Fault
LOP
The controller displays 'LOP', and the generator will not start or shuts down shortly after starting.
Low Oil Pressure Shutdown
LOUT
Controller displays LOUT or LOW UTILITY, and the generator starts even though utility power seems present.
Low Utility Voltage Sensing Fault
LOV
The controller displays 'LOV', and the generator shuts down or will not accept load.
Low Output Voltage Fault
OC
The controller displays 'OC', and the generator will not start or shuts down shortly after cranking.
Overcrank Fault
OL
The controller displays 'OL', and the generator shuts down when loads are applied.
Overload Fault
SEN
Controller displays SEN or SENSOR FAULT, and may prevent starting.
Engine Sensor Input Fault
UF
The controller displays 'UF', and the generator shuts down or will not transfer load.
Underfrequency / Engine Underspeed Fault
Symptom
Corrosion or rust visible inside the generator enclosure, on wiring, or on engine components.
Corrosion and Moisture Intrusion
Symptom
Fuel smell around generator or visible fuel leakage from unit.
Fuel Leak
Symptom
Generator cranks but will not start (no error code displayed).
No-Start Condition Without Logged Fault
Symptom
Generator enclosure panels rattle or vibrate loudly during operation.
Loose Enclosure Panels
Symptom
Generator fails to run scheduled weekly exercise (no start at the programmed time).
Exercise Function Not Operating
Symptom
Generator is excessively loud or has unusual knocking or rattling noises during operation.
Abnormal Mechanical Noise
Symptom
Generator runs but does not transfer power to the house during an outage.
Failure to Transfer Load
Symptom
Generator runs but frequently trips its internal or external breaker.
Repeated Breaker Tripping
Symptom
Generator runs rough, surges, or hunts at no load.
Unstable Engine Speed / Surging
Symptom
Generator starts and runs, but output voltage or frequency is out of specification when measured with a meter.
Out-of-Spec Voltage or Frequency
Symptom
Generator starts but immediately shuts down after a few seconds, no code or only generic shutdown.
Run-Then-Stop Condition
Symptom
Generator transfers power but house lights flicker or dim when large loads start.
Voltage Sag Under Load
Symptom
Generator vibrates excessively, causing enclosure or nearby structures to shake.
Excessive Vibration
Symptom
Generator will not crank at all when a power outage occurs (no click, no attempt to start).
No-Crank on Utility Failure
Symptom
Ice or snow buildup around the generator causing poor performance or shutdowns in winter.
Environmental Obstruction / Cold Weather Operation Issues
Symptom
Remote monitoring system or Wi-Fi module shows the generator offline or not reporting status.
Remote Monitoring Communication Failure
Symptom
Starter cranks slowly or intermittently, especially in cold weather.
Weak Cranking Performance
Symptom
Strong exhaust smell or fumes entering nearby building during generator operation.
Exhaust Fume Intrusion
| Error Code | Symptom | Fault Type | Guide |
|---|---|---|---|
| COMM |
Controller displays COMM or COMMS LOSS, and remote monitoring or ATS communication fails.
|
Communication Bus Fault | View Details |
| ESTOP |
Controller displays ESTOP or EMERGENCY STOP, and the generator will not crank.
|
Emergency Stop Circuit Active | View Details |
| EXER |
Controller displays EXER FAIL or EXERCISE FAILED after a scheduled exercise period.
|
Failed Exercise Run | View Details |
| HBT |
The controller displays 'HBT' or 'HIGH BAT', and may shut down charging or log a fault.
|
High Battery Voltage Fault | View Details |
| HET |
Controller displays HET or HIGH ENG TEMP, and the generator shuts down during or shortly after running.
|
High Engine Temperature Shutdown | View Details |
| HF |
The controller displays 'HF', and the generator shuts down or refuses to transfer load.
|
Overfrequency / Engine Overspeed Fault | View Details |
| HOV |
The controller displays 'HOV', and the generator shuts down or drops load.
|
High Output Voltage Fault | View Details |
| IGN |
Controller displays IGN or IGNITION FAULT, and the generator cranks but does not start.
|
Ignition System Failure | View Details |
| LOAC |
Controller displays LOAC or NO AC, and the generator runs but the transfer switch does not transfer the load.
|
Loss of AC Sensing / No Output Detected by Controller | View Details |
| LOBT |
The controller displays 'LOBT' or 'LOW BAT', and the generator will not crank or cranks slowly.
|
Low Battery Voltage Fault | View Details |
| LOF |
Controller displays LOF, and the generator shuts down or will not start.
|
Loss of Frequency / Loss of Engine Speed Signal | View Details |
| LOFUEL |
Controller displays LO FUEL or LOW FUEL (LP tank models), and the generator will not run a full cycle.
|
Low Fuel Level / Fuel Supply Fault | View Details |
| LOP |
The controller displays 'LOP', and the generator will not start or shuts down shortly after starting.
|
Low Oil Pressure Shutdown | View Details |
| LOUT |
Controller displays LOUT or LOW UTILITY, and the generator starts even though utility power seems present.
|
Low Utility Voltage Sensing Fault | View Details |
| LOV |
The controller displays 'LOV', and the generator shuts down or will not accept load.
|
Low Output Voltage Fault | View Details |
| OC |
The controller displays 'OC', and the generator will not start or shuts down shortly after cranking.
|
Overcrank Fault | View Details |
| OL |
The controller displays 'OL', and the generator shuts down when loads are applied.
|
Overload Fault | View Details |
| SEN |
Controller displays SEN or SENSOR FAULT, and may prevent starting.
|
Engine Sensor Input Fault | View Details |
| UF |
The controller displays 'UF', and the generator shuts down or will not transfer load.
|
Underfrequency / Engine Underspeed Fault | View Details |
| – |
Corrosion or rust visible inside the generator enclosure, on wiring, or on engine components.
|
Corrosion and Moisture Intrusion | View Details |
| – |
Fuel smell around generator or visible fuel leakage from unit.
|
Fuel Leak | View Details |
| – |
Generator cranks but will not start (no error code displayed).
|
No-Start Condition Without Logged Fault | View Details |
| – |
Generator enclosure panels rattle or vibrate loudly during operation.
|
Loose Enclosure Panels | View Details |
| – |
Generator fails to run scheduled weekly exercise (no start at the programmed time).
|
Exercise Function Not Operating | View Details |
| – |
Generator is excessively loud or has unusual knocking or rattling noises during operation.
|
Abnormal Mechanical Noise | View Details |
| – |
Generator runs but does not transfer power to the house during an outage.
|
Failure to Transfer Load | View Details |
| – |
Generator runs but frequently trips its internal or external breaker.
|
Repeated Breaker Tripping | View Details |
| – |
Generator runs rough, surges, or hunts at no load.
|
Unstable Engine Speed / Surging | View Details |
| – |
Generator starts and runs, but output voltage or frequency is out of specification when measured with a meter.
|
Out-of-Spec Voltage or Frequency | View Details |
| – |
Generator starts but immediately shuts down after a few seconds, no code or only generic shutdown.
|
Run-Then-Stop Condition | View Details |
| – |
Generator transfers power but house lights flicker or dim when large loads start.
|
Voltage Sag Under Load | View Details |
| – |
Generator vibrates excessively, causing enclosure or nearby structures to shake.
|
Excessive Vibration | View Details |
| – |
Generator will not crank at all when a power outage occurs (no click, no attempt to start).
|
No-Crank on Utility Failure | View Details |
| – |
Ice or snow buildup around the generator causing poor performance or shutdowns in winter.
|
Environmental Obstruction / Cold Weather Operation Issues | View Details |
| – |
Remote monitoring system or Wi-Fi module shows the generator offline or not reporting status.
|
Remote Monitoring Communication Failure | View Details |
| – |
Starter cranks slowly or intermittently, especially in cold weather.
|
Weak Cranking Performance | View Details |
| – |
Strong exhaust smell or fumes entering nearby building during generator operation.
|
Exhaust Fume Intrusion | View Details |
No matching codes found
Advertisements