Code 45
Onan
Low Fuel Level Shutdown
Generator shuts down; Code 45 displayed, indicating low fuel level (if equipped with a level sensor).
Advertisements
Possible Causes
Fuel tank level below shutdown threshold, faulty fuel level sensor, wiring issue between sensor and controller, incorrect sensor calibration.
How to Fix / Troubleshooting
Safety first: Disable auto-start. Handle fuel in a well-ventilated area away from ignition sources.
- Verify fuel level: Physically check the fuel tank level. If low, refill with the correct fuel type (diesel, gasoline, LP) and bleed the system if required.
- Inspect fuel level sensor: Check the sensor mounting on the tank and its wiring harness. Look for corrosion or damage.
- Sensor test: If the tank is adequately filled but Code 45 persists, test the sensor resistance or output per Onan specifications. Replace if out of range.
- Calibration: Some systems require calibration of the level sensor in the controller. Follow the service manual procedure if applicable.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Fuel Level Sensor
Check Price on Amazon
We may earn a commission from links on this page.