F15
Bauknecht
Dryer Heater Relay / Control Fault
The drying cycle ends prematurely or does not start; F15 is displayed.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck or failed dryer heater relay on the main control board, wiring fault to the dryer heater, control board logic error
How to Fix / Troubleshooting
Safety first: Unplug the appliance.
Basic checks:
- Verify heater and NTC: Confirm that the dryer heater and NTC sensor are functional (refer to F13 and F14 steps). If both are good, focus on the control board.
- Inspect control board: Remove the top cover and inspect the main control board for burnt areas near the dryer relay.
Resolution: If the board shows damage or F15 persists despite functional heater and sensors, replace the main control board.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Main Control Board (Power Module)
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements