F08
Hotpoint Heater relay or heating circuit stuck on/off

The machine fills and may tumble but does not heat; an F08 error appears.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted heater relay on PCB, Heating element shorted to earth, Wiring short in heating circuit, Faulty main control board

How to Fix / Troubleshooting

Safety: Unplug the machine. Heating components can retain heat; allow sufficient time for them to cool.

  • Insulation test (advanced): Disconnect the heating element wires and use a megohmmeter or insulation tester between each heating element terminal and earth. Any low resistance indicates an earth fault; replace the heating element.
  • Visual inspection: Check the heating element and its wiring for burn marks or melted insulation. Replace damaged parts.
  • Check PCB: Access the main control board and inspect the heater relay area for scorching or cracked solder joints. If the relay is visibly damaged or stuck, replace the main control board (PCB).
  • Do not bypass safety: Never bypass the heater relay or earth connections. If you are unsure, contact a qualified technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control Board (PCB)
Check Price on Amazon