E19
Grundig
Internal Valve / Recirculation Fault
Washer shows E19; internal valve or recirculation system malfunction (on models with recirculation or detergent dosing).
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck recirculation valve, Blocked internal recirculation hose, Faulty detergent dosing valve (if equipped), Wiring fault to internal valve coil
How to Fix / Troubleshooting
Safety first: Unplug the washer and turn off water supply.
Step-by-step checks:
- Identify internal valves: Consult the Grundig service diagram for your model to locate any recirculation or dosing valves.
- Inspect hoses and valves: Remove hoses connected to the internal valve and check for blockages from lint or detergent residue. Clean thoroughly.
- Test valve coils: Measure resistance of the valve coils with a multimeter. Replace any coil that is open or shorted.
- Check wiring: Ensure connectors to the valve are secure and wires are not damaged.
- Replace faulty valve: If the valve is mechanically stuck or the coil is defective, replace the valve assembly with the correct Grundig part.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Recirculation Valve
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements