E02
UniMac Fill Timeout / Water Inlet Error

Washer fills slowly or not at all; display shows E02.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Clogged inlet screens on UniMac water valves, Closed or partially closed building water supply valves, Defective hot or cold water inlet valve coil, Low building water pressure

How to Fix / Troubleshooting

Safety first: Turn off power and close both hot and cold water supply valves before disconnecting hoses.

  • Verify water supply: Confirm that the building shutoff valves for hot and cold are fully open. Check that other fixtures have normal pressure.
  • Clean inlet screens: Disconnect the fill hoses from the back of the washer. Inspect the metal screens inside the UniMac inlet valve ports for debris or scale. Clean gently with a small brush; do not puncture the screens.
  • Check hoses: Ensure hoses are not kinked or collapsed. Replace if bulged or cracked.
  • Test inlet valve coils: With power off, remove the top or rear panel to access the water inlet valve assembly. Use a multimeter to measure coil resistance; compare to UniMac specifications. Replace the inlet valve assembly if a coil is open or shorted.
  • Run a test fill: After reassembly, restore water and power, then run a fill test. If E02 persists despite good supply and a new valve, the control board may not be energizing the valve correctly and should be checked by a technician.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Water Inlet Valve Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements