E04
UniMac Water Level / Pressure Switch Error

Washer overfills or shows E04 with water level errors; may attempt to drain immediately after filling.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked air dome or pressure hose, Loose pressure hose connection at tub or switch, Defective water level pressure switch, Faulty control board water level circuit

How to Fix / Troubleshooting

Safety first: Unplug the washer before accessing the pressure switch or internal hoses.

  • Inspect pressure hose: Locate the small rubber or plastic hose running from the tub air dome to the pressure switch on UniMac washers. Check for kinks, cracks, or disconnections. Reattach securely if loose.
  • Clear air dome: Remove the hose from the tub connection and blow gently through it to ensure it is clear. If blocked, clean the air dome port on the tub of detergent residue or lint.
  • Check for water in hose: Any water trapped in the pressure hose can cause false readings. Shake out water and reinstall.
  • Test pressure switch: With a multimeter, test continuity across the switch terminals while applying gentle air pressure to the port (use a short piece of hose and blow lightly). If the switch does not change state as specified, replace the pressure switch.
  • Control board: If the hose and switch are good but E04 persists, the main control may be misinterpreting the signal and should be evaluated by a technician.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Water Level Pressure Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements