E16
UniMac Secondary Water Level Sensor Error

Washer shows E16 and may not fill or may overfill; often related to secondary water level or overflow sensor.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective high-level pressure switch, Blocked secondary air trap, Wiring fault to secondary level sensor, Control misinterpretation of level signals

How to Fix / Troubleshooting

Safety first: Disconnect power and water supply before servicing level sensors.

  • Locate secondary sensor: Many UniMac washers use a second pressure switch for high water level. Identify this switch and its hose.
  • Inspect and clear hose: Remove the hose and ensure it is free of soap residue or lint. Clean the air trap on the tub.
  • Test switch: Use a multimeter to check continuity changes as you apply gentle air pressure. Replace the switch if it does not operate correctly.
  • Check wiring: Verify the harness from the secondary switch to the control is intact and properly connected.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

High-Level Pressure Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements