UniMac
No Power / Main Power Supply Failure
Washer will not power on at all; no lights or display, unit appears dead.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Tripped circuit breaker, Blown line fuse on UniMac control, Faulty power cord, Failed main control power supply section
How to Fix / Troubleshooting
Safety first: Before opening the machine, ensure the circuit is de-energized at the breaker if you will be working on internal wiring.
- Check building power: Verify the outlet has correct voltage using a meter or by plugging in another device. Reset any tripped breakers or replace blown fuses in the building panel.
- Inspect power cord: Look for cuts, burns, or loose connections at the strain relief. Replace the cord if damaged.
- Internal fuse: Many UniMac washers have an internal line fuse on the control board or power entry module. With power disconnected, access the control area and test/inspect the fuse. Replace only with the exact type and rating.
- Control board power supply: If fuses and power are good but the unit remains dead, the control board's low-voltage power supply may have failed. Board replacement is typically required and should be done by a qualified technician.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Machine Control Board
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements