E60
V-ZUG
General Heating System Fault
Washer shows E60; heating-related general error
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective heater, Faulty NTC sensor, Wiring issues in heating circuit, Control module heater relay fault
How to Fix / Troubleshooting
Safety first: Disconnect mains power and allow the appliance to cool before working on the heater circuit.
- 1. Confirm heating issue: Run a hot program and check if water remains cold and E60 appears.
- 2. Inspect heater and NTC: Follow the steps for E05 and E22 to test the heating element and NTC sensor.
- 3. Check wiring: Ensure all heater and NTC connectors are secure and free from corrosion or burning.
- 4. Replace faulty parts: Install a new V-ZUG heating element or NTC sensor as indicated by testing.
- 5. Technician service: If hardware is good, the control module's heater relay or triac may be defective and should be replaced by a professional.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Heating Element
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements