E70
V-ZUG Temperature Sensor Calibration / Range Fault

Washer displays E70; temperature sensing error

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect NTC value, Wrong replacement sensor fitted, Control module calibration error, Wiring resistance causing misreading

How to Fix / Troubleshooting

Safety first: Disconnect mains power before testing sensors or wiring.

  • 1. Verify correct part: Ensure any previously replaced NTC sensor is the correct V-ZUG part number for your model.
  • 2. Measure NTC curve: Using a multimeter, measure NTC resistance at different temperatures (room temperature and warmed in your hand) and compare to V-ZUG specifications.
  • 3. Inspect wiring: Check for corroded connectors or extended wiring that could add resistance and skew readings.
  • 4. Replace NTC: If readings are out of range, install a new, correct V-ZUG NTC sensor.
  • 5. Technician calibration: If E70 persists, the control module may require software calibration or replacement by a V-ZUG technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

NTC Temperature Sensor
Check Price on Amazon