F32
Whirlpool
Pressure Switch Failure
Washer shows F32, often related to pressure switch or water level sensing.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective pressure switch, blocked pressure hose, air leak in pressure system, wiring fault to switch
How to Fix / Troubleshooting
Safety first: Disconnect power and water supply.
Step-by-step:
- Inspect hose: Remove and clear the pressure hose. Check for splits or loose connections.
- Check air dome: Clean any residue where the hose connects to the tub.
- Test switch: Verify switch operation with a meter while applying pressure (per tech sheet). Replace if not switching correctly.
- Inspect wiring: Ensure the harness to the switch is intact and secure.
When to call a technician: If the control board is not reading a good switch, professional service is recommended.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Water Level Pressure Switch
Check Price on Amazon
We may earn a commission from links on this page.