F32
Whirlpool Pressure Switch Failure

Washer shows F32, often related to pressure switch or water level sensing.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective pressure switch, blocked pressure hose, air leak in pressure system, wiring fault to switch

How to Fix / Troubleshooting

Safety first: Disconnect power and water supply.

Step-by-step:

  • Inspect hose: Remove and clear the pressure hose. Check for splits or loose connections.
  • Check air dome: Clean any residue where the hose connects to the tub.
  • Test switch: Verify switch operation with a meter while applying pressure (per tech sheet). Replace if not switching correctly.
  • Inspect wiring: Ensure the harness to the switch is intact and secure.

When to call a technician: If the control board is not reading a good switch, professional service is recommended.