H51
Buderus
Low Water Pressure / Flow Fault
Error H51 displayed; the heater may shut down during operation.
Advertisements
Possible Causes
Insufficient system pressure, Faulty water pressure sensor, Blocked strainers or filters, Leak in the system causing pressure drop
How to Fix / Troubleshooting
Safety: Turn off power. Be cautious when opening valves; hot water may be present.
- Check system pressure: Read the pressure gauge on the heater or system. Compare to the recommended cold fill pressure in the Buderus manual.
- Top up system: If pressure is low, open the filling loop or make-up valve and slowly add water until the correct pressure is reached. Close the valve securely afterward.
- Bleed air: Bleed radiators or air vents to remove trapped air, then recheck pressure and top up if needed.
- Inspect for leaks: Look for visible leaks at valves, joints, and around the heater. Repair any leaks found.
- Check pressure sensor: If pressure is correct but H51 persists, test the water pressure sensor according to Buderus procedures and replace if faulty.
- Restore and test: Restore power and verify that H51 clears and that the heater operates normally.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Water Pressure Sensor / Filling Loop Components
Check Price on Amazon