E08
Eldom
Power Supply/Voltage Error
The display shows E08; the heater does not heat or only heats intermittently.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Supply voltage out of range, loose terminal block connections, internal power supply fault on control PCB.
How to Fix / Troubleshooting
Safety: Work only with the power off. Mains voltage is lethal.
Steps:
- Check supply voltage: Have a qualified person measure the voltage at the heater input terminals. Ensure it matches the rating on the Eldom nameplate (e.g., 230V AC).
- Inspect terminal block: Remove the cover over the mains connection. Tighten all screws on the terminal block and check for discoloration or melting.
- Look for burnt components: On the control PCB, inspect the low-voltage power supply section (transformer or SMPS) for burned parts or bulging capacitors.
- Reset and test: After tightening connections, restore power and see if E08 clears. Persistent E08 with correct voltage usually indicates a defective control PCB.
- Replace PCB: If the internal power supply is defective, replace the control PCB/power module with an Eldom-approved part.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Eldom Terminal Block/Control PCB
Check Price on Amazon
We may earn a commission from links on this page.