F41
Protherm Flow Temperature Sensor / Control Deviation

F41 displayed; appliance may not regulate power correctly.

Advertisements

Possible Causes

Slow or drifting NTC sensor, poor thermal contact to pipe, control algorithm detecting unstable readings, wiring interference.

How to Fix / Troubleshooting

Safety first: Isolate power and allow the unit to cool.

  • Check sensor mounting: Ensure the flow NTC is firmly attached to the pipe or in its pocket, with thermal paste if specified.
  • Inspect wiring: Keep sensor cables away from high-voltage or ignition cables.
  • Replace NTC: If readings are unstable or out of tolerance, replace the flow NTC sensor.
  • PCB check: If a new sensor does not resolve F41, the PCB input may be faulty.

Warning: Incorrect temperature control can lead to scalding or poor performance; verify operation after repair.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Primary Flow NTC Sensor
Check Price on Amazon

We may earn a commission from links on this page.