F15
Viessmann
Condensate Drain Fault
F15 error, unit indicates a condensate or drainage problem.
Advertisements
Possible Causes
Blocked condensate trap, frozen condensate discharge pipe, incorrectly installed condensate hose, faulty condensate level sensor (if fitted).
How to Fix / Troubleshooting
Safety: Switch off power. Condensate is mildly acidic; wear gloves and eye protection when handling.
- Inspect condensate trap: Locate the plastic condensate trap at the base of the heat exchanger. Remove and flush it with clean water to remove sludge and debris.
- Check discharge pipe: Follow the condensate pipe to its termination. Ensure it is not frozen, kinked, or blocked. Thaw frozen sections gently with warm towels; do not use open flames.
- Verify slope: Ensure the condensate pipe slopes continuously downward with no sags that can collect water.
- Check level sensor: If your model uses a condensate level sensor, inspect and clean it according to the manual. Replace if corroded or not switching.
- Reset and test: Reassemble the trap, restore power, and run the heater. Confirm that condensate flows freely during operation.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Condensate Trap
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements