E1 338
Worcester Bosch Unstable Flame / Ionisation Fault

Boiler displays E1 338, which may indicate an unstable flame or ionisation signal.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Partially blocked burner, Incorrect gas pressure, Faulty ionisation electrode, Flue gas recirculation

How to Fix / Troubleshooting

Safety first: Combustion-related work must be performed by a Gas Safe engineer.

Engineer actions:

  • Inspect and clean the burner and primary heat exchanger surfaces.
  • Check and clean the ionisation electrode; ensure its correct position in the flame.
  • Measure gas inlet and burner pressures and adjust or replace the gas valve as required.
  • Inspect the flue system for recirculation issues and correct any installation faults.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Ionisation Electrode
Check Price on Amazon

We may earn a commission from links on this page.