E17
AquaUnique
Temperature Sensor Fault
E17 error, and the unit reports brine tank temperature out of range.
Advertisements
Possible Causes
Failed brine tank temperature sensor, Sensor wiring damaged, Brine tank exposed to freezing or excessive heat, Control board sensor input failure
How to Fix / Troubleshooting
Safety first: Unplug the unit before handling any sensors or wiring. Avoid working in standing water around the softener.
Step-by-step:
- Check environment: Ensure that the softener is installed in a location within the recommended temperature range (typically 2–40°C). Protect it from freezing.
- Inspect sensor: Locate the AquaUnique brine tank temperature sensor (if equipped) and verify that it is securely mounted and not physically damaged.
- Check wiring: Follow the sensor cable to the control head and ensure that connectors are tight and free of corrosion.
- Power cycle: Restore power and see if E17 clears after the unit stabilizes at room temperature.
When to call a technician: Persistent E17 with normal ambient temperature indicates a failed sensor or control board that should be replaced.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
AquaUnique Brine Tank Temperature Sensor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements